|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
File name: TFS140M.doc version 1.3 28.06.2002 VI TELEFILTER 1. Measurement condition : Filter specification TFS 140 M 1/5 Ambient temperature TA: Input power level: Terminating impedances in fc : 45 C 0 dBm for input: for output: 50 50 0 pF. 0 pF. 2. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 140 M is the minimum of the pass band attenuation a min. The minimum of the pass band attenuation amin is defined as the insertion loss a e. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data Insertion loss : (Reference level) ae fc typ. value 28,5 dB 140,00 MHz 140,23 MHz PB 0,0 dB 0,15 dB 1 arel 50 C tolerance / limit max. 30,5 dB Centre frequency at ambient temperature : Centre frequency at room temperature T=23C: Pass band : ( see theoretical frequency response) Pass band tilt : Deviation from theoretical frequency response 1) (p-p) : fC .... fC fY Deviation from theoretical phase response fC .... fC fY 2) 1) 140,00 0,25 MHz 140,23 0,25 MHz max. 0,01 dB/MHz dB degree max. 0,4 max. 2 (p-p): Relative attenuation at ambient temperature : fC 18 MHz .... fC 100 MHz Group delay at fc : Reflected attenuation compared to main signal Crosstalk attenuation compared to main signal Nyquist frequency Roll-off factor Partitioning factor Phase coefficients : Input power level Temperature coefficient of frequency : Frequency deviation of f c over temperature : Operating temperature range ( OgTR ) : Operable temperature range ( OTR ) : Storage temperature range ( STR ) : 1) dB min. min. min. 40 45 45 dB dB dB 1,467 s 60 dB 60 dB 13,805 MHz 0,25 0,5 p7 = - 0,6715 p13 = 0,01421 p3 = 0,009987 p9 = 0,3920 fY a p p5 = 0,6524 p11 = - 0,110 Tcf p15 = - 0,0006794 max. 15 dBm - 75 ppm / K fc(Hz) = Tcf(ppm/K) x (T - TA) x fC (MHz) + 45 C - 40 C ... + 85 C - 40 C ... + 85 C Theoretical frequency response : H (x) ( S ( x )) 1 p ; where , x f fY fC for x (1 (1 a) a) x x (1 (1 a) a ), S (x) 1 2 0 1 cos 2 (x 1 2a a) , for for 2) Theoretical phase response : Ph ( y ) [ p3 y 3 p5 y 5 p7 y 7 p9 y 9 p 11 y 11 p 13 y 13 p 15 y 15 ]( 180 ) [deg] where y f 10 fC [ MHz ] Generated: Checked / approved: W. Dunzow Dr. Bert Wall VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS140M.doc version 1.3 28.06.2002 VI TELEFILTER Filter specification TFS 140 M 2/5 3. Construction and pin connection : (All dimensions in mm) pin grid 2,54 mm TFS 140 M P55 Date-code: M N P ... Date-code 5,0 Max. 6,7 Max. Year+week 2000 2001 2002 ... 13,0 Max. 1 25,0 Max. 0,50Max. 123 678 16 15 14 11 10 9 7X2,54=17,78 4. 50 - Matching network : 7,62 Pin 3 Pin 2 Pin 11 Pin 10 Pin 1, 8, 9, 16 Pin 6, 7, 14, 15 input input RF Return output output RF Return package ground not connected 8 7 6 9 10 11 50 50 3 2 1 14 15 16 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS140M.doc version 1.3 28.06.2002 VI TELEFILTER Filter specification TFS 140 M 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 2. Vibration: 3. Change of temperature 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS140M.doc version 1.3 28.06.2002 VI TELEFILTER 6. Soldering temperature conditions : Filter specification TFS 140 M 4/5 1st and 2nd soldering temperature profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C Soldering temperature profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. Table for temperature vs. time during the soldering process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 140 160 180 200 220 240 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS140M.doc version 1.3 28.06.2002 VI TELEFILTER 7. History : Version 1.0 1.1 1.2 Reason of Changes Filter specification TFS 140 M 5/5 Name Dunzow W. Dunzow W. Dunzow W. Date 06.11.2001 13.11.2001 28.05.2002 Generation of development specification according to customer requirements. Correct theoretical phase response according to customer requirements. Generate filter specification. Add typical measured values. Package drawing correction. 1.3 Dunzow W. 28.06.2002 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS140M |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |